Insulation Floor mats rubber sheet
Product name: Insulating rubber sheet Product color: black, red, green, gray Plastic sheet thickness: 3-50mm Sheet width: 80cm, 100cm
Like this product? Share with friends:
Products Details

Insulating pad having a larger volume resistivity and electrical sheet resistance breakdown sheet. Excellent non-polar rubber with NR, SBR and IIR insulating properties. For table or floor insulation material distribution and other workplace.

1718176356158971.jpg

Product name: Insulating rubber sheet

Product color: black, red, green, gray

Plastic sheet thickness: 3-50mm

Sheet width: 80cm, 100cm

Sheet length: Optional

Anti-insulation voltage: 35kv or less

Features: good mechanical properties, excellent insulation properties

Sheet purposes: can be used for flooring and table, power distribution room, 110kv substations, and large-scale chemical plants, smelters, factories, power distribution room and control room floor use.

 

Insulation sheet Features: 1 insulated rubber sheet as a new generation of power distribution room and control room aids laid in power plant power plants and other large chemical manufacturing and smelting plants substation power distribution room or chamber. To assist in the repair process electrician to prevent any parts distribution room leakage caused by power distribution room floor or ground transformer room and other electrified body charged maintenance personnel life-threatening. Power distribution room or transformer room laying insulation pads can prevent the control cabinet or other cabinet due to the long conductive static import ground maintenance personnel to enter the power distribution room, electrical injury is due to static electricity. 2. insulated rubber sheet can also be used for laboratory tables and laboratory or podium laying 3. insulated rubber sheet into the black, red, green, gray and other four colors. Black Material cheapest general requirements and configuration is not high, the most widely used, followed by a red, red, black Material Material superior general distribution room or substation configuration requirements higher insulation sheet can use this color, the best material for the green and gray, green and gray material best quality for high-profile power distribution room and transformer room. In addition, I produced the latest new environmentally friendly insulating rubber sheet pad, when the use of environmentally friendly insulation pads board more environmentally friendly flame retardant rubber smell and no corrosion is an insulating rubber plate our latest listing. For the future direction of the mainstream power plant insulation blanket. New insulation rubber plate made of good natural NR, SBR and IIR and other non-polar rubber insulation for power distribution transformer room work room control room scene countertops and floor coverings of insulation material. 2. insulated rubber sheet

 

Insulation mat / insulation pad

Product Name: insulation pads

Common Specifications: 600mm × 800mm 800mm × 800mm

Pad thickness: 3-50mm

Anti-insulation voltage: 35kv or less

Product color: black, red, green, gray

Features: good mechanical properties, excellent insulation properties

Surface: mainly flat, choose non-slip surface.

Sheet purposes: can be used for flooring and table, power distribution room, 110kv substation, and other venues ground use.

Note: According to user requirements printed: "In operation" and other words.

1718176479225524.jpg

1718176479898094.jpg

Insulation board insulation baffles → → → high voltage insulation baffle insulation pad insulation pads → → fiberglass insulation baffles

Product Overview: insulated baffle material used epoxy and E-glass fiber cloth impregnated with a pressurized drying curing and molding.

Features: high density, not hydrophilic, good electrical insulation properties, high mechanical strength, thin profile, light weight, reasonable design, easy assembly and disassembly.

Scope:

1. isolate live parts, limiting the scope of activities electricity operator, security appliance to prevent misuse of power accidents.

2. For live equipment isolated angle iron cross arm on time, such as the replacement drop insurance, adjacent phase arrester for occlusion to limit the scope of human activities, and improve the level of insulation adjacent phase.

3. In the electric power construction job for transformers, switches and other identical segments isolation protection

Main categories: a) with handle insulation baffles b) Normal insulation baffles

Size: 500 × 700mm withstand 30kV

       700 × 1400mm voltage: 80kV

Note: Can be customized according to user requirements.

1718176579720659.jpg

1718176580733339.jpg

Electrical insulation cover insulation cover → → → high voltage insulation cover insulation shield insulating protective mask protective mask Security fiberglass insulation cover fiberglass insulating protective mask

I produced the isolation switch insulation cover with PVC insulation material is refined, in line with the national power industry standard DL408-91, applicable to 3-10kV oil switch, isolating switch or circuit safety measures during maintenance.

Use and features:

The insulating jacket in by bus side isolation switch (or knife) on the knife, the purpose is to directly gate insulation to prevent personal injury and equipment that have fallen into the knife with the bus or manual error caused by the combined knife damage and other accidents.

Note: This product working environment -40 - + 60 , relative humidity 90%, the replacement period of three years, pre-test once every six months.





 